APQ 80/540 Chromatic Focal Shift
APQ 80/540 UV–VIS–SWIR Polychromat Chromatic Focal Shift
2 / 8
APQ 80/540 Matrix Spot Diagram
APQ 80/540 UV–VIS–SWIR Polychromat Matrix Spot Diagram
3 / 8
APQ 80/540 Geometric MTF vs. Field
APQ 80/540 UV–VIS–SWIR Polychromat Geometric MTF vs. Field
4 / 8
APQ 80/540 Transverse Ray Fan
APQ 80/540 UV–VIS–SWIR Polychromat Transverse Ray Fan
5 / 8
APQ 80/540 RMS Spot Radius vs. Field
APQ 80/540 UV–VIS–SWIR Polychromat RMS Spot Radius vs. Field
6 / 8
APQ 80/540 Field Curvature / Distortion
APQ 80/540 UV–VIS–SWIR Polychromat Field Curvature / Distortion
7 / 8
APQ 80/540 Polychromatic FFT PSF
APQ 80/540 UV–VIS–SWIR Polychromat Polychromatic FFT PSF
8 / 8
APQ 80/540 Optical Path Difference
APQ 80/540 UV–VIS–SWIR Polychromat Optical Path Difference

APQ 80/540 UV–VIS–SWIR WF Polychromat

APQ 80/540 UV–VIS–SWIR WF Polychromat

365–2500 nm UV–VIS–NIR–SWIR
80 mm / 540 mm / f/6.75
4,55° champ complet non vignetté
Cercle image non vignetté env. Ø 42.9 mm
Strehl polychromatique (Huygens) 0.997

Prix
sur demande

Délai
sur demande

Demande


  • Description
  • Spécifications
  • Évaluation du design optique
  • Applications

APQ 80/540 UV–VIS–SWIR WF Polychromat

Le Polychromat APQ 80/540 UV–VIS–SWIR WF associe une ouverture libre de 80 mm et une focale de 540 mm à f/6.75 avec un champ complet non vignetté de 4,55°.

Le système optique est corrigé en continu sur 365–2500 nm dans un plan image commun. Le cercle image non vignetté obtenu est d’environ Ø 42.9 mm.

Cette combinaison de correction polychromatique à large bande, de rapport d’ouverture rapide et de grand champ non vignetté est destinée aux applications exigeantes en astronomie, science, télédétection et optronique.

Détecteur Teledyne adapté

Pour exploiter le domaine SWIR jusqu’à 2,5 µm, le Teledyne CHROMA-A est particulièrement bien adapté : 1280 × 480 pixels avec un pas de 30 µm donnent une surface active de 38,4 × 14,4 mm et une diagonale d’environ 41,0 mm. Le cercle image non vignetté d’environ Ø 42,9 mm est ainsi presque entièrement utilisé. CHROMA-A couvre 380–2500 nm ; un canal ou détecteur UV séparé est nécessaire pour la plage 365–380 nm.

Type optique
UV–VIS–SWIR WF Polychromat

Ouverture libre
80 mm

Distance focale
540 mm

Rapport d’ouverture
f/6.75

Domaine spectral
365–2500 nm

champ complet non vignetté
4,55° (±2.275°)

Cercle image non vignetté
Ø 42.9 mm

Détecteur Teledyne adapté
Teledyne CHROMA-A, 1280 × 480 pixels, pas 30 µm, surface active 38.4 × 14.4 mm, diagonale env. 41.0 mm, 380–2500 nm

Tirage arrière
230 mm

Longueurs d’onde évaluées
12: 365, 404.7, 486.1, 546.1, 632.8, 656.3, 852.1, 1014, 1128.6, 1529.6, 1970.1, 2500 nm

Décalage focal chromatique maximal
15.467 µm

Plage de mise au point limitée par la diffraction
99.508 µm

Strehl polychromatique (Huygens)
0.997

Rayon d’Airy (longueur d’onde principale)
4.5 µm

Courbure de champ sagittale
-0.0081 mm

Courbure de champ tangentielle
-0.0351 mm

Évaluation du design optique

APQ 80/540 Décalage focal chromatique
APQ 80/540 Décalage focal chromatique
APQ 80/540 Diagramme de spots matriciel
APQ 80/540 Diagramme de spots matriciel

APQ 80/540 MTF géométrique vs. champ
APQ 80/540 MTF géométrique vs. champ
APQ 80/540 Aberration transversale des rayons
APQ 80/540 Aberration transversale des rayons

APQ 80/540 Rayon RMS des spots vs. champ
APQ 80/540 Rayon RMS des spots vs. champ
APQ 80/540 Courbure de champ / Distorsion
APQ 80/540 Courbure de champ / Distorsion

APQ 80/540 FFT-PSF polychromatique
APQ 80/540 FFT-PSF polychromatique
APQ 80/540 Différence de chemin optique
APQ 80/540 Différence de chemin optique

Exemple de détecteur Teledyne: Teledyne CHROMA-A

Le format du capteur est choisi en fonction du cercle image non vignetté afin que la FPA Teledyne sélectionnée exploite le champ disponible sans vignettage marginal tout en couvrant le SWIR jusqu’à 2,5 µm.

Astronomie et imagerie grand champ

Le grand champ non vignetté convient aux relevés, aux objets célestes étendus, aux mosaïques et aux détecteurs grand format tout en conservant la correction à large bande.

Observation satellitaire et télédétection

Le grand champ et la courte focale permettent l’acquisition rapide de vastes zones du ciel et d’objets, notamment pour l’observation satellitaire, SSA/SDA/SST et la télédétection multispectrale.

Défense, sécurité et optronique ; science et industrie

Le plan image corrigé à large bande convient aux essais et à l’étalonnage de capteurs, à l’observation des matériaux et procédés, à l’imagerie scientifique et aux systèmes multicapteurs spécifiques.