APQ JENA
Deutsch
English
Français
Español
Italiano
Hindi
1 / 8
APQ 160/1120 Chromatic Focal Shift
APQ 160/1120 UV–VIS–SWIR Polychromat Chromatic Focal Shift
2 / 8
APQ 160/1120 Matrix Spot Diagram
APQ 160/1120 UV–VIS–SWIR Polychromat Matrix Spot Diagram
3 / 8
APQ 160/1120 Geometric MTF vs. Field
APQ 160/1120 UV–VIS–SWIR Polychromat Geometric MTF vs. Field
4 / 8
APQ 160/1120 Transverse Ray Fan
APQ 160/1120 UV–VIS–SWIR Polychromat Transverse Ray Fan
5 / 8
APQ 160/1120 RMS Spot Radius vs. Field
APQ 160/1120 UV–VIS–SWIR Polychromat RMS Spot Radius vs. Field
6 / 8
APQ 160/1120 Field Curvature / Distortion
APQ 160/1120 UV–VIS–SWIR Polychromat Field Curvature / Distortion
7 / 8
APQ 160/1120 Polychromatic FFT PSF
APQ 160/1120 UV–VIS–SWIR Polychromat Polychromatic FFT PSF
8 / 8
APQ 160/1120 Optical Path Difference
APQ 160/1120 UV–VIS–SWIR Polychromat Optical Path Difference
Home / Products / APQ UV–VIS–SWIR WF / Back / APQ 160/1120 WF

APQ 160/1120 UV–VIS–SWIR WF Polychromat

APQ 160/1120 UV–VIS–SWIR WF Polychromat

365–2500 nm UV–VIS–NIR–SWIR
160 mm / 1120 mm / f/7
4.55° full unvignetted field
Unvignetted image circle approx. Ø 89.0 mm
Polychromatic Strehl (Huygens) 0.9909

Price
on request

Lead time
on request

Inquiry


  • Description
  • Specification
  • Optical Design Evaluation
  • Applications

APQ 160/1120 UV–VIS–SWIR WF Polychromat

The APQ 160/1120 UV–VIS–SWIR WF Polychromat combines a 160 mm clear aperture and 1120 mm focal length with f/7 and a 4.55° full unvignetted field.

The optical system is continuously corrected over 365–2500 nm in a common image plane. The resulting unvignetted image circle is approximately Ø 89.0 mm.

This combination of broadband polychromatic correction, fast focal ratio and large unvignetted field is intended for demanding astronomical, scientific, remote-sensing and optronic imaging tasks.

Matched Teledyne detector

For use of the SWIR range to 2.5 µm, the Teledyne H4RG-15 is particularly suitable: 4096 × 4096 pixels at 15 µm pitch provide an active area of 61.44 × 61.44 mm and a diagonal of approximately 86.9 mm. This nearly fills the approximately Ø 89.0 mm unvignetted image circle. The H4RG-15 with 2.5 µm cutoff is a large-format HgCdTe SWIR detector for astronomical and scientific instrumentation; a separate UV/VIS channel may be used where sensitivity down to 365 nm is required.

Optical type
UV–VIS–SWIR WF Polychromat

Clear aperture
160 mm

Focal length
1120 mm

F-number
f/7

Spectral range
365–2500 nm

full unvignetted field
4.55° (±2.275°)

Unvignetted image circle
Ø 89.0 mm

Suitable Teledyne detector
Teledyne H4RG-15, 4096 × 4096 pixels, 15 µm pitch, 61.44 × 61.44 mm active area, approx. 86.9 mm diagonal, HgCdTe, 2.5 µm cutoff

Back focus
450 mm

Evaluated wavelengths
12: 365, 404.7, 486.1, 546.1, 632.8, 656.3, 852.1, 1014, 1128.6, 1529.6, 1970.1, 2500 nm

Maximum chromatic focal shift
40.5264 µm

Diffraction-limited focus range
107.016 µm

Polychromatic Strehl (Huygens)
0.9909

Airy radius (primary wavelength)
4.66 µm

Field curvature sagittal
-0.0185 mm

Field curvature tangential
-0.0631 mm

Optical Design Evaluation

APQ 160/1120 Chromatic Focal Shift
APQ 160/1120 Chromatic Focal Shift
APQ 160/1120 Matrix Spot Diagram
APQ 160/1120 Matrix Spot Diagram

APQ 160/1120 Geometric MTF vs. Field
APQ 160/1120 Geometric MTF vs. Field
APQ 160/1120 Transverse Ray Fan
APQ 160/1120 Transverse Ray Fan

APQ 160/1120 RMS Spot Radius vs. Field
APQ 160/1120 RMS Spot Radius vs. Field
APQ 160/1120 Field Curvature / Distortion
APQ 160/1120 Field Curvature / Distortion

APQ 160/1120 Polychromatic FFT PSF
APQ 160/1120 Polychromatic FFT PSF
APQ 160/1120 Optical Path Difference
APQ 160/1120 Optical Path Difference

Teledyne detector example: Teledyne H4RG-15

The sensor format is matched to the unvignetted image circle so that the selected Teledyne FPA can use the available field without edge vignetting while exploiting the SWIR range to 2.5 µm.

Astronomy and wide-field imaging

Large unvignetted fields support survey imaging, extended celestial objects, mosaics and large-format detectors while preserving broadband correction.

Satellite observation and remote sensing

The wide field and short focal length support rapid acquisition of large sky and object fields, including satellite observation, SSA/SDA/SST and multispectral remote sensing.

Defense, security and optronics; science and industry

The broadband corrected image plane supports sensor testing, calibration, material and process observation, scientific imaging and customer-specific multisensor systems.